- Products
- Market Solutions & Services
- Insight
- Tools & Resources
- About Nexans Australia
- Search
- Contact us
- Compare
- Sign in
Olex-Flexs PVC Earth 0.6/1kV 50mm2 Green/Yellow
Olex-Flexs PVC Earth 0.6/1kV 50mm2 Green/Yellow
Olex-Flexs PVC Earth 0.6/1kV 50mm2 Green/Yellow
Read more- Nexans ref. : BAAX05AA001AAHT
- Country ref. : BAAX05AA001AAHT
- EAN : 9319215500078
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 5000.1
One core flexible multiple stranded plain annealed copper, 0.6/1 kV, V-90 PVC, insulated flexible earth cable.
For use with flexible Versolex and other PVC single core cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Green / yellow
Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Type of conductor
Stranded flexible
With Green/Yellow core
Yes
Dimensional characteristics
Dimensional characteristics
Approximate weight
48.5 kg/100m
Cable length
1 m
Conductor cross-section
50 mm²
Nominal insulation thickness
1.4 mm
Nominal overall diameter
12.2 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.47 Ohm/km
Insulation resistance at 20°C
4.5 MOhm.km
Max. DC resistance of the conductor at 20°C
0.386 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Flexible
Maximum Pulling Tension
1 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
73 mm
Minimum Bend Radius - Installed
49 mm
Resources
Resources
PVC Insulated - Current carrying capacity table three phase (in Amps)
Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰CConductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
50.0 | 181.0 | 156.0 | 146.0 | 119.0 | 95.0 | 0.0 | 144.0 | 168.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
PVC Insulated - Current carrying capacity table single phase (in Amps)
Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰CConductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
50.0 | 187.0 | 177.0 | 146.0 | 138.0 | 110.0 | 0.0 | 168.0 | 186.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |