Olex-Flexs Flexible PVC Earth
Olex-Flexs Flexible PVC Earth
One core flexible multiple stranded plain annealed copper, 0.6/1 kV, PVC insulated flexible earth cable. Best Practice Guidelines.
Read moreOlex-Flexs PVC Earth 0.6/1kV 10mm2 Green/Yellow NEW
Nexans ref. BAAX01AA001AAHT - Country ref. BAAX01AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.2 kN
- Minimum Bend Radius - During Installation (under Tension): 38 mm
- Minimum Bend Radius - Installed: 19 mm
Olex-Flexs PVC Earth 0.6/1kV 16mm2 Green/Yellow
Nexans ref. BAAX02AA001AAHT - Country ref. BAAX02AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 0.32 kN
- Minimum Bend Radius - During Installation (under Tension): 44 mm
- Minimum Bend Radius - Installed: 22 mm
Olex-Flexs PVC Earth 0.6/1kV 25mm2 Green/Yellow
Nexans ref. BAAX03AA001AAHT - Country ref. BAAX03AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 0.5 kN
- Minimum Bend Radius - During Installation (under Tension): 54 mm
- Minimum Bend Radius - Installed: 27 mm
Olex-Flexs PVC Earth 0.6/1kV 35mm2 Green/Yellow
Nexans ref. BAAX04AA001AAHT - Country ref. BAAX04AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 61 mm
- Minimum Bend Radius - Installed: 31 mm
Olex-Flexs PVC Earth 0.6/1kV 50mm2 Green/Yellow
Nexans ref. BAAX05AA001AAHT - Country ref. BAAX05AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Maximum Pulling Tension: 1 kN
- Minimum Bend Radius - During Installation (under Tension): 73 mm
- Minimum Bend Radius - Installed: 49 mm
Olex-Flexs PVC Earth 0.6/1kV 70mm2 Green/Yellow
Nexans ref. BAAX63AA001AAHT - Country ref. BAAX63AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Maximum Pulling Tension: 1.4 kN
- Minimum Bend Radius - During Installation (under Tension): 83 mm
- Minimum Bend Radius - Installed: 56 mm
Olex-Flexs PVC Earth 0.6/1kV 95mm2 Green/Yellow
Nexans ref. BAAX64AA001AAHT - Country ref. BAAX64AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Maximum Pulling Tension: 1.9 kN
- Minimum Bend Radius - During Installation (under Tension): 96 mm
- Minimum Bend Radius - Installed: 64 mm
Olex-Flexs PVC Earth 0.6/1kV 120mm2 Green/Yellow
Nexans ref. BAAE87AA001AAHT - Country ref. BAAE87AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Maximum Pulling Tension: 2.4 kN
- Minimum Bend Radius - During Installation (under Tension): 109 mm
- Minimum Bend Radius - Installed: 73 mm
Olex-Flexs PVC Earth 0.6/1kV 150mm2 Green/Yellow
Nexans ref. BAAE88AA001AAHT - Country ref. BAAE88AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Maximum Pulling Tension: 3 kN
- Minimum Bend Radius - During Installation (under Tension): 121 mm
- Minimum Bend Radius - Installed: 80 mm
Olex-Flexs PVC Earth 0.6/1kV 185mm2 Green/Yellow
Nexans ref. BAAE89AA001AAHT - Country ref. BAAE89AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Maximum Pulling Tension: 3.7 kN
- Minimum Bend Radius - During Installation (under Tension): 134 mm
- Minimum Bend Radius - Installed: 90 mm
Olex-Flexs PVC Earth 0.6/1kV 240mm2 Green/Yellow
Nexans ref. BAAE90AA001AAHT - Country ref. BAAE90AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Maximum Pulling Tension: 4.8 kN
- Minimum Bend Radius - During Installation (under Tension): 229 mm
- Minimum Bend Radius - Installed: 152 mm
Olex-Flexs PVC Earth 0.6/1kV 300mm2 Green/Yellow
Nexans ref. BAAE91AA001AAHT - Country ref. BAAE91AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Maximum Pulling Tension: 6 kN
- Minimum Bend Radius - During Installation (under Tension): 255 mm
- Minimum Bend Radius - Installed: 170 mm
Olex-Flexs PVC Earth 0.6/1kV 400mm2 Green/Yellow
Nexans ref. BAAE92AA001AAHT - Country ref. BAAE92AA001AAHT
- Packaging: Cut to length (m)
- Conductor cross-section: 400 mm²
- Maximum Pulling Tension: 8 kN
- Minimum Bend Radius - During Installation (under Tension): 288 mm
- Minimum Bend Radius - Installed: 192 mm
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 5000.1
One core flexible multiple stranded plain annealed copper, 0.6/1 kV, V-90 PVC, insulated flexible earth cable.
For use with flexible Versolex and other PVC single core cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Resources
Resources
PVC Insulated - Current carrying capacity table three phase (in Amps)
Copper Conductor
Insulation PVC
Maximum Conductor Temperature 75⁰C
Conductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
1.0 | 16.0 | 14.0 | 13.0 | 12.0 | 10.0 | 6.0 | 16.0 | 19.0 |
1.5 | 20.0 | 17.0 | 16.0 | 15.0 | 12.0 | 8.0 | 20.0 | 24.0 |
2.5 | 29.0 | 25.0 | 23.0 | 21.0 | 17.0 | 12.0 | 27.0 | 33.0 |
4.0 | 38.0 | 33.0 | 31.0 | 28.0 | 23.0 | 16.0 | 36.0 | 43.0 |
6.0 | 49.0 | 42.0 | 40.0 | 35.0 | 28.0 | 20.0 | 45.0 | 53.0 |
10.0 | 67.0 | 58.0 | 54.0 | 47.0 | 37.0 | 27.0 | 59.0 | 70.0 |
16.0 | 89.0 | 77.0 | 72.0 | 62.0 | 50.0 | 36.0 | 78.0 | 90.0 |
25.0 | 120.0 | 103.0 | 97.0 | 81.0 | 64.0 | 48.0 | 100.0 | 117.0 |
35.0 | 148.0 | 127.0 | 119.0 | 100.0 | 80.0 | 59.0 | 122.0 | 140.0 |
50.0 | 181.0 | 156.0 | 146.0 | 119.0 | 95.0 | 0.0 | 144.0 | 168.0 |
70.0 | 230.0 | 197.0 | 184.0 | 152.0 | 122.0 | 0.0 | 180.0 | 205.0 |
95.0 | 287.0 | 246.0 | 230.0 | 183.0 | 147.0 | 0.0 | 217.0 | 250.0 |
120.0 | 335.0 | 287.0 | 267.0 | 217.0 | 173.0 | 0.0 | 252.0 | 283.0 |
150.0 | 385.0 | 330.0 | 308.0 | 244.0 | 195.0 | 0.0 | 283.0 | 317.0 |
185.0 | 447.0 | 383.0 | 357.0 | 284.0 | 227.0 | 0.0 | 325.0 | 365.0 |
240.0 | 535.0 | 457.0 | 426.0 | 331.0 | 265.0 | 0.0 | 377.0 | 422.0 |
300.0 | 620.0 | 529.0 | 492.0 | 388.0 | 311.0 | 0.0 | 434.0 | 488.0 |
400.0 | 726.0 | 615.0 | 573.0 | 442.0 | 353.0 | 0.0 | 492.0 | 553.0 |
500.0 | 846.0 | 710.0 | 661.0 | 523.0 | 418.0 | 0.0 | 571.0 | 641.0 |
630.0 | 990.0 | 817.0 | 760.0 | 588.0 | 471.0 | 0.0 | 639.0 | 723.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
PVC Insulated - Current carrying capacity table single phase (in Amps)
Copper Conductor
Insulation PVC
Maximum Conductor Temperature 75⁰C
Conductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
1.0 | 16.0 | 16.0 | 13.0 | 13.0 | 11.0 | 6.0 | 18.0 | 21.0 |
1.5 | 21.0 | 21.0 | 16.0 | 18.0 | 14.0 | 8.0 | 23.0 | 26.0 |
2.5 | 30.0 | 29.0 | 23.0 | 24.0 | 20.0 | 12.0 | 32.0 | 36.0 |
4.0 | 40.0 | 39.0 | 31.0 | 32.0 | 25.0 | 16.0 | 41.0 | 47.0 |
6.0 | 51.0 | 49.0 | 40.0 | 41.0 | 33.0 | 20.0 | 52.0 | 58.0 |
10.0 | 69.0 | 67.0 | 54.0 | 54.0 | 44.0 | 27.0 | 69.0 | 77.0 |
16.0 | 92.0 | 89.0 | 72.0 | 70.0 | 56.0 | 36.0 | 89.0 | 99.0 |
25.0 | 124.0 | 119.0 | 97.0 | 94.0 | 75.0 | 48.0 | 116.0 | 129.0 |
35.0 | 153.0 | 145.0 | 119.0 | 112.0 | 90.0 | 59.0 | 139.0 | 155.0 |
50.0 | 187.0 | 177.0 | 146.0 | 138.0 | 110.0 | 0.0 | 168.0 | 186.0 |
70.0 | 238.0 | 223.0 | 184.0 | 170.0 | 136.0 | 0.0 | 206.0 | 228.0 |
95.0 | 295.0 | 276.0 | 230.0 | 212.0 | 169.0 | 0.0 | 252.0 | 278.0 |
120.0 | 344.0 | 321.0 | 267.0 | 242.0 | 193.0 | 0.0 | 287.0 | 316.0 |
150.0 | 395.0 | 367.0 | 308.0 | 282.0 | 225.0 | 0.0 | 329.0 | 354.0 |
185.0 | 459.0 | 424.0 | 358.0 | 320.0 | 256.0 | 0.0 | 373.0 | 408.0 |
240.0 | 549.0 | 505.0 | 428.0 | 381.0 | 305.0 | 0.0 | 438.0 | 472.0 |
300.0 | 636.0 | 582.0 | 495.0 | 0.0 | 0.0 | 0.0 | 496.0 | 546.0 |
400.0 | 744.0 | 676.0 | 577.0 | 0.0 | 0.0 | 0.0 | 575.0 | 621.0 |
500.0 | 867.0 | 780.0 | 668.0 | 0.0 | 0.0 | 0.0 | 649.0 | 721.0 |
630.0 | 1014.0 | 897.0 | 770.0 | 0.0 | 0.0 | 0.0 | 750.0 | 816.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania