70mm2 Cu Flexible Envirolex 110C

Description

Description

Standards

  • Product
    AS/NZS 5000.1
  • Test
    AS/NZS 4507; IEC 60332-3 Cat.A

ENVIROLEX® flexible single core cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.

  • 0.6/1kV cables,
  • Flexible, X-HF-110 insulated to AS/NZS 5000.1
  • HFS-110-TP sheathed to AS/NZS 5000.1
  • 110°C continuous
  • Low fire hazard - Flame retardant
  • PVC-free
  • Meets physical property requirements of 125°C XLPO insulation to UL 1581


*Also known as ENVIROLEX® Single Core

110; Flexible; LS0H, LSZH; LFH; Envirolex; Green Star; Mains; Sub Mains; Flame Retardant

RHE-3 to AS/NZ 4507. IEC60332-3 Cat A Bunched Flame Propagation.

Suitable for public buildings and infrastructure projects.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Black
Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
X-HF-110
Outer sheath
HFS-110-TP
Type of conductor
Stranded flexible
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Approximate weight
74.9 kg/100m
Conductor cross-section
70 mm²
Conductor diameter
11.1 mm
Diameter over insulation
13.3 mm
Neutral conductor section (when smaller)
- mm²
Nominal insulation thickness
1.1 mm
Nominal outer sheath thickness
1.4 mm
Nominal overall diameter
16.2 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Conductor AC resistance at 50 Hz
0.369 Ohm/km
Inductive reactance at 50Hz - flat touching
0.102 Ohm/km
Inductive reactance at 50Hz - trefoil
0.0869 Ohm/km
Insulation resistance at 20°C
240 MOhm.km
Max. DC resistance of the conductor at 20°C
0.272 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible
Maximum Pull Tension of Conductor
1 kN
Maximum Pulling Tension
1.4 kN

Usage characteristics

Usage characteristics

Fire safety
Maximum operating temperature
110 °C
Minimum Bend Radius - During Installation (under Tension)
100 mm
Minimum Bend Radius - Installed
65 mm

Resources

Resources

ENVIROLEX® Flexible Single Core 110°C - Current carrying capacity table single phase (in Amps)

Insulation type: R-HF-110, R-E-110 OR X-HF-110 Maximum conductor temperature: 110°C Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
70.0 351 329 273 263 210 0 345 266 287
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual wiring enclosure

ENVIROLEX® Flexible Single Core 110°C - Current carrying capacity table three phase (in Amps)

Insulation type: R-HF-110, R-E-110 OR X-HF-110 Maximum conductor temperature: 110°C Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
70.0 340 292 273 234 187 0 290 229 257
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual wiring enclosure

Selling & delivery Information

Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close