185mm2 Cu Flexible Envirolex 110C

Description

Description

Standards

  • Product
    AS/NZS 5000.1
  • Test
    AS/NZS 4507; IEC 60332-3 Cat.A

ENVIROLEX® flexible single core cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.

  • 0.6/1kV cables,
  • Flexible, X-HF-110 insulated to AS/NZS 5000.1
  • HFS-110-TP sheathed to AS/NZS 5000.1
  • 110°C continuous
  • Low fire hazard - Flame retardant
  • PVC-free
  • Meets physical property requirements of 125°C XLPO insulation to UL 1581


*Also known as ENVIROLEX® Single Core

110; Flexible; LS0H, LSZH; LFH; Envirolex; Green Star; Mains; Sub Mains; Flame Retardant

RHE-3 to AS/NZ 4507. IEC60332-3 Cat A Bunched Flame Propagation.

Suitable for public buildings and infrastructure projects.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Black
Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
X-HF-110
Outer sheath
HFS-110-TP
Type of conductor
Stranded flexible
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Approximate weight
178.0 kg/100m
Conductor cross-section
185 mm²
Conductor diameter
18.4 mm
Diameter over insulation
21.6 mm
Neutral conductor section (when smaller)
- mm²
Nominal insulation thickness
1.6 mm
Nominal outer sheath thickness
1.6 mm
Nominal overall diameter
24.8 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Conductor AC resistance at 50 Hz
0.145 Ohm/km
Inductive reactance at 50Hz - flat touching
0.0973 Ohm/km
Inductive reactance at 50Hz - trefoil
0.0821 Ohm/km
Insulation resistance at 20°C
210 MOhm.km
Max. DC resistance of the conductor at 20°C
0.106 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible
Maximum Pull Tension of Conductor
4 kN
Maximum Pulling Tension
2.98 kN

Usage characteristics

Usage characteristics

Fire safety
-
Maximum operating temperature
110 °C
Minimum Bend Radius - During Installation (under Tension)
150 mm
Minimum Bend Radius - Installed
99 mm

Resources

Resources

ENVIROLEX® Flexible Single Core 110°C - Current carrying capacity table single phase (in Amps)

Insulation type: R-HF-110, R-E-110 OR X-HF-110 Maximum conductor temperature: 110°C Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
185.0 660 611 516 481 385 0 585 464 503
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual wiring enclosure

ENVIROLEX® Flexible Single Core 110°C - Current carrying capacity table three phase (in Amps)

Insulation type: R-HF-110, R-E-110 OR X-HF-110 Maximum conductor temperature: 110°C Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
185.0 644 553 516 438 350 0 489 404 448
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual wiring enclosure

Selling & delivery Information

Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close