VERSOLEX® Flexible Multicore 90°C

Products

CU VERSOLEX 2x1.5mm2+E Black

Nexans ref. PTFR04AA002CXHF - Country ref. PTFR04AA002CXHF

  • Packaging: Cut to length (m)
  • Approximate weight: 13.0 kg/100m
  • Conductor cross-section: 1.5 mm²
  • Nominal overall diameter: 10.3 mm
  • Number of cores: 2

 

CU VERSOLEX 2x2.5mm2+E Black

Nexans ref. PTFR05AA002CXHF - Country ref. PTFR05AA002CXHF

  • Packaging: Cut to length (m)
  • Approximate weight: 17.0 kg/100m
  • Conductor cross-section: 2.5 mm²
  • Nominal overall diameter: 11.3 mm
  • Number of cores: 2

 

CU VERSOLEX 2x4mm2+E Black

Nexans ref. PTFR06AA002CXHF - Country ref. PTFR06AA002CXHF

  • Packaging: Cut to length (m)
  • Approximate weight: 21.0 kg/100m
  • Conductor cross-section: 4 mm²
  • Nominal overall diameter: 11.9 mm
  • Number of cores: 2

 

CU VERSOLEX 3x2.5mm2+E Black

Nexans ref. PTFR05AA003CXRJ - Country ref. PTFR05AA003CXRJ

  • Packaging: Cut to length (m)
  • Approximate weight: 21.0 kg/100m
  • Conductor cross-section: 2.5 mm²
  • Nominal overall diameter: 12.2 mm
  • Number of cores: 3

 

CU VERSOLEX 3x4mm2+E Black

Nexans ref. PTFR06AA003CXRJ - Country ref. PTFR06AA003CXRJ

  • Packaging: Cut to length (m)
  • Approximate weight: 26.0 kg/100m
  • Conductor cross-section: 4 mm²
  • Nominal overall diameter: 13.0 mm
  • Number of cores: 3

 

CU VERSOLEX 4x1.5mm2+E Black

Nexans ref. PTFR04AA004CXEM - Country ref. PTFR04AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 18.0 kg/100m
  • Conductor cross-section: 1.5 mm²
  • Nominal overall diameter: 12.0 mm
  • Number of cores: 4

 

CU VERSOLEX 4x10mm2+E Black

Nexans ref. PTFX01AA004CXEM - Country ref. PTFX01AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 63.0 kg/100m
  • Conductor cross-section: 10 mm²
  • Nominal overall diameter: 18.5 mm
  • Number of cores: 4

 

CU VERSOLEX 4x16mm2+E Black

Nexans ref. PTFX02AA004CXEM - Country ref. PTFX02AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 87.0 kg/100m
  • Conductor cross-section: 16 mm²
  • Nominal overall diameter: 21.4 mm
  • Number of cores: 4

 

CU VERSOLEX 4x2.5mm2+E Black

Nexans ref. PTFR05AA004CXEM - Country ref. PTFR05AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 24.0 kg/100m
  • Conductor cross-section: 2.5 mm²
  • Nominal overall diameter: 13.1 mm
  • Number of cores: 4

 

CU VERSOLEX 4x25mm2+E Black

Nexans ref. PTFX03AA004CXEM - Country ref. PTFX03AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 116.0 kg/100m
  • Conductor cross-section: 25 mm²
  • Nominal overall diameter: 24.7 mm
  • Number of cores: 4

 

CU VERSOLEX 4x35mm2+E Black

Nexans ref. PTFX04AA004CXEM - Country ref. PTFX04AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 158.0 kg/100m
  • Conductor cross-section: 35 mm²
  • Nominal overall diameter: 28.0 mm
  • Number of cores: 4

 

CU VERSOLEX 4x4mm2+E Black

Nexans ref. PTFR06AA004CXEM - Country ref. PTFR06AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 31.0 kg/100m
  • Conductor cross-section: 4 mm²
  • Nominal overall diameter: 14.1 mm
  • Number of cores: 4

 

CU VERSOLEX 4x50mm2+E Black

Nexans ref. PTFX05AA004CXEM - Country ref. PTFX05AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 227.0 kg/100m
  • Conductor cross-section: 50 mm²
  • Nominal overall diameter: 32.9 mm
  • Number of cores: 4

 

CU VERSOLEX 4x6mm2+E Black

Nexans ref. PTFR07AA004CXEM - Country ref. PTFR07AA004CXEM

  • Packaging: Cut to length (m)
  • Approximate weight: 40.0 kg/100m
  • Conductor cross-section: 6 mm²
  • Nominal overall diameter: 15.2 mm
  • Number of cores: 4

 

Description

Description

Standards

  • Product
    AS/NZS 5000.1

Overview

VERSOLEX® Flexible Multicore 90°C is Nexans range of premium flexible power cables suited to a wide range of commercial and industrial applications. Robust and durable, VERSOLEX is the first choice for flexibility and reliability.

Specifications

  • PVC components meet Best Practice Guidelines for PVC in the built environment.
  • Available in Low Smoke Zero Halogen (low fire hazard). See ENVIROLEX - Low Fire Hazard.
  • In systems intended to operate continuously at 90°C maximum operating temperature, Nexans Envirolex - Low Fire Hazard is recommended. Note that designing and operating a system continuously at maximum operating temperature is unlikely to be energy efficient over the life of the asset.

Application

  • For fixed application.
  • Submersible up to 500m
  • Maximum operating temperature 90°C

Features & Benefits

  • Class 5 & 6 flexible conductor
  • 0.6/1kV cables,
  • X-90 (XLPE) insulated
  • TPE sheathed to AS/NZS5000.1 (Power),
  • Copper conductors, 90°C.
  • Submersible up to 500m
  • Characteristics

    Characteristics

    Construction characteristics

    Construction characteristics

    Conductor flexibility
    Class 5
    Conductor material
    Copper
    Conductor shape
    Circular
    Insulation
    X-90
    Outer sheath
    TPE
    Sheath colour
    Black

    Dimensional characteristics

    Dimensional characteristics

    Number of earth cores
    1

    Electrical characteristics

    Electrical characteristics

    Rated Voltage Uo/U (Um)
    0,6/1 kV

    Usage characteristics

    Usage characteristics

    Maximum operating temperature
    90 °C
    Minimum operating temperature
    -40 °C

    Resources

    Resources

    Multicore Flexible - Current carrying capacities single phase (in Amps)

    Flexible copper conductor

    Maximum conductor temperature: 90°C

    Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

    Conductor cross-section
    mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
    1.0 19.0 18.0 14.0 9.0 16.0 13.0 8.0 27.0 20.0
    1.5 24.0 23.0 18.0 11.0 20.0 16.0 10.0 33.0 25.0
    2.5 32.0 30.0 24.0 15.0 27.0 22.0 14.0 44.0 33.0
    4.0 43.0 40.0 32.0 20.0 35.0 28.0 18.0 58.0 43.0
    6.0 55.0 51.0 41.0 26.0 44.0 35.0 22.0 73.0 54.0
    10.0 78.0 72.0 58.0 36.0 62.0 50.0 31.0 100.0 74.0
    16.0 103.0 96.0 77.0 48.0 80.0 64.0 40.0 129.0 95.0
    25.0 136.0 128.0 102.0 64.0 106.0 85.0 53.0 165.0 124.0
    35.0 169.0 158.0 127.0 79.0 129.0 103.0 64.0 200.0 150.0
    50.0 213.0 199.0 159.0 0.0 163.0 131.0 0.0 245.0 186.0
    70.0 269.0 251.0 201.0 0.0 207.0 165.0 0.0 299.0 231.0
    95.0 322.0 300.0 240.0 0.0 242.0 194.0 0.0 350.0 271.0
    120.0 381.0 355.0 284.0 0.0 289.0 231.0 0.0 403.0 318.0
    150.0 438.0 408.0 326.0 0.0 328.0 262.0 0.0 454.0 360.0
    185.0 499.0 464.0 371.0 0.0 375.0 300.0 0.0 506.0 407.0
    240.0 596.0 554.0 443.0 0.0 439.0 351.0 0.0 590.0 475.0
    300.0 682.0 633.0 506.0 0.0 511.0 409.0 0.0 664.0 544.0
    400.0 811.0 751.0 601.0 0.0 595.0 475.0 0.0 768.0 631.0
    500.0 932.0 862.0 689.0 0.0 699.0 559.0 0.0 864.0 729.0
    Unenclosed spaced
    Unenclosed touching
    Unenclosed and partially surrounded by thermal insulation
    Unenclosed and completely surrounded by thermal insulation
    Enclosed conduit in air
    Enclosed, partially surrounded by thermal insulation
    Enclosed, completely surrounded by thermal insulation
    Buried direct
    Underground Wiring Enclosure

    Multicore Flexible - Current carrying capacities three phase (in Amps)

    Flexible copper conductor

    Maximum conductor temperature: 90°C

    Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

    Conductor cross-section
    mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
    1.0 16.0 15.0 12.0 8.0 14.0 11.0 7.0 23.0 17.0
    1.5 20.0 19.0 15.0 10.0 17.0 13.0 8.0 28.0 21.0
    2.5 27.0 26.0 20.0 13.0 23.0 18.0 11.0 37.0 28.0
    4.0 36.0 34.0 27.0 17.0 29.0 24.0 15.0 49.0 36.0
    6.0 46.0 43.0 35.0 22.0 37.0 29.0 18.0 61.0 45.0
    10.0 66.0 61.0 49.0 31.0 52.0 42.0 26.0 84.0 62.0
    16.0 87.0 81.0 65.0 41.0 67.0 53.0 33.0 108.0 79.0
    25.0 116.0 108.0 87.0 54.0 89.0 71.0 44.0 139.0 103.0
    35.0 144.0 135.0 108.0 67.0 111.0 89.0 56.0 168.0 127.0
    50.0 182.0 170.0 136.0 0.0 136.0 109.0 0.0 206.0 155.0
    70.0 230.0 214.0 171.0 0.0 173.0 138.0 0.0 251.0 193.0
    95.0 275.0 256.0 205.0 0.0 202.0 162.0 0.0 293.0 226.0
    120.0 327.0 303.0 242.0 0.0 242.0 194.0 0.0 337.0 266.0
    150.0 375.0 348.0 278.0 0.0 274.0 219.0 0.0 380.0 300.0
    185.0 428.0 396.0 317.0 0.0 314.0 251.0 0.0 424.0 339.0
    240.0 511.0 472.0 378.0 0.0 379.0 303.0 0.0 493.0 402.0
    300.0 584.0 539.0 0.0 0.0 0.0 0.0 0.0 554.0 452.0
    400.0 692.0 638.0 0.0 0.0 0.0 0.0 0.0 639.0 537.0
    500.0 794.0 730.0 0.0 0.0 0.0 0.0 0.0 716.0 602.0
    Unenclosed spaced
    Unenclosed touching
    Unenclosed and partially surrounded by thermal insulation
    Unenclosed and completely surrounded by thermal insulation
    Enclosed conduit in air
    Enclosed, partially surrounded by thermal insulation
    Enclosed, completely surrounded by thermal insulation
    Buried direct
    Underground Wiring Enclosure

    Contact us

    Topics on which you wish to get more informations:

    Required fields*

    Please check your entry and try again.

    An email address must contain a single @

    Personal data protector

    You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

    Thank you!

    Thanks for contacting us. We will be in touch with you shortly.

    Error

    An error occurred. Please try again.

    Close

    Contact us

    Required fields*

    Please check your entry and try again.

    An email address must contain a single @

    Personal data protector

    You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

    Thank you!

    Thanks for contacting us. We will be in touch with you shortly.

    Error

    An error occurred. Please try again.

    Close