NEXANS LFH Flexible Multicore 110°C

Products

NEXANS LFH 4C+E 16mm2 Cu Flexible Multicore

Nexans ref. HZKR09AA004CXAA

  • Packaging: Cut to length (m)
  • Approximate weight: 83.5 kg/100m
  • Conductor cross-section: 16 mm²
  • Conductor diameter: 5.3 mm
  • Earth conductor cross section: 6 mm²
  • Nominal overall diameter: 21.4 mm

 

NEXANS LFH 4C+E 25mm2 Cu Flexible Multicore

Nexans ref. HZKX60AA004CXAA

  • Packaging: Cut to length (m)
  • Approximate weight: 121.0 kg/100m
  • Conductor cross-section: 25 mm²
  • Conductor diameter: 6.6 mm
  • Earth conductor cross section: 6 mm²
  • Nominal overall diameter: 24.7 mm

 

NEXANS LFH 4C+E 35mm2 Cu Flexible Multicore

Nexans ref. HZKX61AA004CXAA

  • Packaging: Cut to length (m)
  • Approximate weight: 163.0 kg/100m
  • Conductor cross-section: 35 mm²
  • Conductor diameter: 7.8 mm
  • Earth conductor cross section: 10 mm²
  • Nominal overall diameter: 28.1 mm

 

NEXANS LFH 4C+E 50mm2 Cu Flexible Multicore

Nexans ref. HZKX62AA004CXAA

  • Packaging: Cut to length (m)
  • Approximate weight: 237.0 kg/100m
  • Conductor cross-section: 50 mm²
  • Conductor diameter: 9.4 mm
  • Earth conductor cross section: 16 mm²
  • Nominal overall diameter: 32.9 mm

 

Description

Description

Standards

  • National
    AS/NZS 4507; AS/NZS 5000.1

NEXANS LFH flexible multicore cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, cable is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.

  • Class 5 flexible conductor
  • 0.6/1kV cables,
  • Flexible, X-HF-110 insulated
  • HFS-110-TP sheathed to AS/NZS 5000.1 (Power), copper conductors),
  • 110°C continuous, Low smoke - zero halogen.
  • Low Fire Hazard cable
  • PVC-free
  • Meets physical property requirements of 125°C XLPO insulation to UL 1581

110; Flexible; LS0H; LFH; Envirolex; Mains; Sub Mains; Flame Retardant

Reduced fire hazard - ideal for public buidlings and infrastructure projects where reduced smake hazard and time to evacuate is important.

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Black
Conductor flexibility
Class 5
Insulation
X-HF-110
Outer sheath
HFS-110-TP

Dimensional characteristics

Dimensional characteristics

Number of cores
4

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Usage characteristics

Usage characteristics

Fire safety
-
Maximum operating temperature
110 °C

Resources

Resources

ENVIROLEX® Flexible Multicore 110°C - Current carrying capacities single phase (in Amps)

Flexible copper conductor

Maximum conductor temperature: 110°C

Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu
1.0 24.0 23.0 20.0 16.0 11.0 30.0 23.0
1.5 30.0 28.0 24.0 19.0 14.0 37.0 29.0
2.5 40.0 38.0 32.0 26.0 19.0 49.0 37.0
4.0 53.0 50.0 43.0 35.0 25.0 65.0 49.0
6.0 67.0 63.0 54.0 43.0 31.0 81.0 62.0
10.0 94.0 88.0 75.0 60.0 44.0 110.0 84.0
16.0 124.0 116.0 100.0 80.0 58.0 142.0 109.0
25.0 163.0 154.0 129.0 104.0 77.0 182.0 139.0
35.0 202.0 190.0 163.0 130.0 95.0 221.0 171.0
50.0 254.0 238.0 202.0 161.0 0.0 270.0 209.0
70.0 318.0 299.0 257.0 205.0 0.0 329.0 259.0
95.0 381.0 357.0 303.0 243.0 0.0 384.0 304.0
120.0 450.0 421.0 362.0 290.0 0.0 443.0 357.0
150.0 515.0 482.0 412.0 330.0 0.0 500.0 403.0
185.0 586.0 547.0 474.0 379.0 0.0 558.0 456.0
240.0 698.0 652.0 577.0 462.0 0.0 650.0 541.0
300.0 799.0 745.0 656.0 525.0 0.0 733.0 611.0
400.0 949.0 884.0 801.0 641.0 0.0 850.0 727.0
500.0 1091.0 1014.0 913.0 730.0 0.0 959.0 820.0
Unenclosed spaced
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Undergound Wiring Enclosure

ENVIROLEX® Flexible Multicore 110°C - Current carrying capacities three phase (in Amps)

Flexible copper conductor

Maximum conductor temperature: 110°C

Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu
1.0 21.0 19.0 17.0 13.0 10.0 26.0 20.0
1.5 26.0 24.0 21.0 16.0 12.0 32.0 24.0
2.5 34.0 32.0 27.0 22.0 16.0 42.0 31.0
4.0 45.0 42.0 36.0 29.0 21.0 55.0 41.0
6.0 57.0 54.0 46.0 37.0 27.0 68.0 51.0
10.0 80.0 75.0 65.0 52.0 38.0 93.0 71.0
16.0 106.0 99.0 84.0 67.0 50.0 120.0 91.0
25.0 140.0 131.0 112.0 90.0 66.0 153.0 118.0
35.0 173.0 162.0 137.0 110.0 81.0 186.0 143.0
50.0 218.0 204.0 175.0 140.0 0.0 227.0 178.0
70.0 273.0 255.0 217.0 173.0 0.0 277.0 217.0
95.0 327.0 306.0 263.0 210.0 0.0 323.0 259.0
120.0 387.0 360.0 306.0 245.0 0.0 373.0 298.0
150.0 444.0 413.0 356.0 285.0 0.0 420.0 341.0
185.0 505.0 470.0 402.0 321.0 0.0 469.0 381.0
240.0 602.0 559.0 489.0 391.0 0.0 546.0 453.0
300.0 688.0 638.0 0.0 0.0 0.0 614.0 509.0
400.0 817.0 756.0 0.0 0.0 0.0 711.0 606.0
500.0 936.0 865.0 0.0 0.0 0.0 799.0 680.0
Unenclosed spaced
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Undergound Wiring Enclosure

Selling & delivery Information

Nexans Fire Safety Offer NEXANS LFH Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close