ENVIROLEX® Single Core 110°C Flexible
ENVIROLEX® Single Core 110°C Flexible
ENVIROLEX
Single core flexible copper conductor, 0.6/1kV X-HF-110 insulated, HFS-110-TP sheathed to AS/NZS 5000.1, Low smoke zero halogen insulation and sheath, 110°C continuous
Read more10mm2 Cu Flexible Envirolex 110C
Nexans ref. BZHX01AA001CXNA - Country ref. BZHX01AA001CXNA
- Packaging: Cut to length (m)
- Approximate weight: 13.9 kg/100m
- Conductor cross-section: 10 mm²
- Nominal overall diameter: 8.6 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 0.2 kN
- Minimum Bend Radius - During Installation (under Tension): 52 mm
- Minimum Bend Radius - Installed: 34 mm
120mm2 Cu Flexible Envirolex 110C
Nexans ref. BZHE87AA001CXNA - Country ref. BZHE87AA001CXNA
- Packaging: Cut to length (m)
- Approximate weight: 118.0 kg/100m
- Conductor cross-section: 120 mm²
- Nominal overall diameter: 20.4 mm
- Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 2.4 kN
- Minimum Bend Radius - During Installation (under Tension): 120 mm
- Minimum Bend Radius - Installed: 82 mm
150mm2 Cu Flexible Envirolex 110C
Nexans ref. BZHE88AA001CXNA - Country ref. BZHE88AA001CXNA
- Packaging: Cut to length (m)
- Approximate weight: 146.0 kg/100m
- Conductor cross-section: 150 mm²
- Nominal overall diameter: 22.5 mm
- Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
- Maximum Pull Tension of Conductor: 3 kN
- Maximum Pulling Tension: 2.7 kN
- Minimum Bend Radius - During Installation (under Tension): 140 mm
- Minimum Bend Radius - Installed: 90 mm
16mm2 Cu Flexible Envirolex 110C
Nexans ref. BZHX02AA001CXNA - Country ref. BZHX02AA001CXNA
- Packaging: Cut to length (m)
- Approximate weight: 20.0 kg/100m
- Conductor cross-section: 16 mm²
- Nominal overall diameter: 9.8 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 0.32 kN
- Minimum Bend Radius - During Installation (under Tension): 59 mm
- Minimum Bend Radius - Installed: 39 mm
185mm2 Cu Flexible Envirolex 110C
Nexans ref. BZHE89AA001CXNA - Country ref. BZHE89AA001CXNA
- Packaging: Cut to length (m)
- Approximate weight: 178.0 kg/100m
- Conductor cross-section: 185 mm²
- Nominal overall diameter: 24.8 mm
- Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
- Maximum Pull Tension of Conductor: 4 kN
- Maximum Pulling Tension: 2.98 kN
- Minimum Bend Radius - During Installation (under Tension): 150 mm
- Minimum Bend Radius - Installed: 99 mm
Description
Description
Standards
-
ProductAS/NZS 5000.1
-
TestAS/NZS 4507; IEC 60332-3 Cat.A
ENVIROLEX® flexible single core cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.
Application
- 0.6/1kV cables,
- Flexible, X-HF-110 insulated to AS/NZS 5000.1
- HFS-110-TP sheathed to AS/NZS 5000.1
- 110°C continuous
- Low fire hazard - Flame retardant
- PVC-free
- Meets physical property requirements of 125°C XLPO insulation to UL 1581
*Also known as ENVIROLEX® Single Core
110; Flexible; LS0H, LSZH; LFH; Envirolex; Green Star; Mains; Sub Mains; Flame Retardant
RHE-3 to AS/NZ 4507. IEC60332-3 Cat A Bunched Flame Propagation.
Suitable for public buildings and infrastructure projects.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
ENVIROLEX® Flexible Single Core 110°C - Current carrying capacity table single phase (in Amps)
Insulation type: R-HF-110, R-E-110 OR X-HF-110
Maximum conductor temperature: 110°C
Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section |
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
Conductor cross-section 1.0 |
|||||||||
Conductor cross-section 1.5 |
|||||||||
Conductor cross-section 2.5 |
|||||||||
Conductor cross-section 4.0 |
|||||||||
Conductor cross-section 6.0 |
|||||||||
Conductor cross-section 10.0 |
|||||||||
Conductor cross-section 16.0 |
|||||||||
Conductor cross-section 25.0 |
|||||||||
Conductor cross-section 35.0 |
|||||||||
Conductor cross-section 50.0 |
|||||||||
Conductor cross-section 70.0 |
|||||||||
Conductor cross-section 95.0 |
|||||||||
Conductor cross-section 120.0 |
|||||||||
Conductor cross-section 150.0 |
|||||||||
Conductor cross-section 185.0 |
|||||||||
Conductor cross-section 240.0 |
|||||||||
Conductor cross-section 300.0 |
|||||||||
Conductor cross-section 400.0 |
|||||||||
Conductor cross-section 500.0 |
|||||||||
Conductor cross-section 630.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Enclosed, partially surrounded by thermal insulation |
Enclosed, completely surrounded by thermal insulation |
Buried direct |
Underground Wiring Enclosure |
Individual wiring enclosure |
ENVIROLEX® Flexible Single Core 110°C - Current carrying capacity table three phase (in Amps)
Insulation type: R-HF-110, R-E-110 OR X-HF-110
Maximum conductor temperature: 110°C
Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section |
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
Conductor cross-section 1.0 |
|||||||||
Conductor cross-section 1.5 |
|||||||||
Conductor cross-section 2.5 |
|||||||||
Conductor cross-section 4.0 |
|||||||||
Conductor cross-section 6.0 |
|||||||||
Conductor cross-section 10.0 |
|||||||||
Conductor cross-section 16.0 |
|||||||||
Conductor cross-section 25.0 |
|||||||||
Conductor cross-section 35.0 |
|||||||||
Conductor cross-section 50.0 |
|||||||||
Conductor cross-section 70.0 |
|||||||||
Conductor cross-section 95.0 |
|||||||||
Conductor cross-section 120.0 |
|||||||||
Conductor cross-section 150.0 |
|||||||||
Conductor cross-section 185.0 |
|||||||||
Conductor cross-section 240.0 |
|||||||||
Conductor cross-section 300.0 |
|||||||||
Conductor cross-section 400.0 |
|||||||||
Conductor cross-section 500.0 |
|||||||||
Conductor cross-section 630.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Enclosed, partially surrounded by thermal insulation |
Enclosed, completely surrounded by thermal insulation |
Buried direct |
Underground Wiring Enclosure |
Individual wiring enclosure |
Selling & delivery Information
Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor