- Products
- Market Solutions & Services
- Insight
- Tools & Resources
- About Nexans Australia
- Search
- Contact us
- Compare
- Sign in
XLP 1X500 PC XLPPVC
XLP 1X500 PC XLPPVC
500mm2 XLPE / PVC SDI Black
Read more- Nexans ref. : BDBP30AA001CXNA
- Country ref. : BDBP30AA001CXNA
- EAN : 99319215277355
Description
Description
Standards
-
NationalAS/NZS 1125; AS/NZS 5000.1
Single core XLPE SDI Cable
- Single core, 0.6/1kV X-90 insulated,
- PVC sheathed to AS/NZS 5000.1,
- Copper conductor, 90°C.
Mains; Submains
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Black
Conductor material
Copper
Type of conductor
Stranded copper
Conductor shape
Circular
Conductor flexibility
Class 2
Insulation
X-90
Outer sheath
PVC
Dimensional characteristics
Dimensional characteristics
Approximate weight
491.0 kg/100m
Cable length
- m
Conductor cross-section
500 mm²
Nominal insulation thickness
2.2 mm
Nominal outer sheath thickness
2.0 mm
Nominal overall diameter
37.0 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.051 Ohm/km
Inductive reactance at 50Hz - flat touching
0.095 Ohm/km
Inductive reactance at 50Hz - trefoil
0.08 Ohm/km
Insulation resistance at 20°C
190 MOhm.km
Max. DC resistance of the conductor at 20°C
0.037 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pull Tension of Conductor
25 kN
Maximum Pulling Tension
4.4 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
330 mm
Minimum Bend Radius - Installed
220 mm
Resources
Resources
XLPE/PVC single core - Current carrying capacity table single phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
500.0 | 1078.0 | 850.0 | 966.0 | 772.0 | 821.0 | 656.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 913.0 | 729.0 | 739.0 | 590.0 | 800.0 | 632.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
XLPE/PVC single core - Current carrying capacity table three phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
500.0 | 1051.0 | 829.0 | 874.0 | 703.0 | 812.0 | 652.0 | 633.0 | 509.0 | 506.0 | 407.0 | 0.0 | 0.0 | 752.0 | 604.0 | 648.0 | 520.0 | 707.0 | 559.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania