- Products
- Market Solutions & Services
- Insight
- Tools & Resources
- About Nexans Australia
- Search
- Contact us
- Compare
- Sign in
XLP 1X150 PC XLPPVC
XLP 1X150 PC XLPPVC
150mm2 XLPE / PVC SDI Black
Read more- Nexans ref. : BDBP24AA001CXNA
- Country ref. : BDBP24AA001CXNA
- EAN : 99319215277300
Description
Description
Standards
-
NationalAS/NZS 1125; AS/NZS 5000.1
Single core XLPE SDI Cable
- Single core, 0.6/1kV X-90 insulated,
- PVC sheathed to AS/NZS 5000.1,
- Copper conductor, 90°C.
Mains; Submains
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Black
Conductor material
Copper
Type of conductor
Compressed copper
Conductor shape
Circular
Conductor flexibility
Class 2
Insulation
X-90
Outer sheath
PVC
Dimensional characteristics
Dimensional characteristics
Approximate weight
152.0 kg/100m
Cable length
- m
Conductor cross-section
150 mm²
Nominal insulation thickness
1.4 mm
Nominal outer sheath thickness
1.6 mm
Nominal overall diameter
21.3 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.153 Ohm/km
Inductive reactance at 50Hz - flat touching
0.1 Ohm/km
Inductive reactance at 50Hz - trefoil
0.084 Ohm/km
Insulation resistance at 20°C
220 MOhm.km
Max. DC resistance of the conductor at 20°C
0.124 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pull Tension of Conductor
11 kN
Maximum Pulling Tension
2.6 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
130 mm
Minimum Bend Radius - Installed
85 mm
Resources
Resources
XLPE/PVC single core - Current carrying capacity table single phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
150.0 | 486.0 | 377.0 | 451.0 | 350.0 | 375.0 | 291.0 | 329.0 | 255.0 | 263.0 | 204.0 | 0.0 | 0.0 | 480.0 | 372.0 | 365.0 | 283.0 | 401.0 | 311.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
XLPE/PVC single core - Current carrying capacity table three phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
150.0 | 472.0 | 366.0 | 403.0 | 313.0 | 375.0 | 291.0 | 295.0 | 229.0 | 236.0 | 183.0 | 0.0 | 0.0 | 400.0 | 310.0 | 320.0 | 249.0 | 358.0 | 277.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania