XLP 1X50 PC 0.6/1.0kV PVC 100m
XLP 1X50 PC 0.6/1.0kV PVC 100m
50mm2 XLPE / PVC SDI Black 100m
Read more- Nexans ref. : BDBC19A1001CXNA
- Country ref. : BDBC19A1001CXNA
- EAN : 9319215476496
Description
Description
Standards
-
NationalAS/NZS 1125; AS/NZS 5000.1
Single core XLPE SDI Cable
- Single core, 0.6/1kV X-90 insulated,
- PVC sheathed to AS/NZS 5000.1,
- Copper conductor, 90°C.
Mains; Submains
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Black
Conductor material
Copper
Type of conductor
Compact copper
Conductor shape
Circular
Conductor flexibility
Class 2
Insulation
X-90
Outer sheath
PVC
Dimensional characteristics
Dimensional characteristics
Approximate weight
52.0 kg/100m
Cable length
100 m
Conductor cross-section
50 mm²
Nominal insulation thickness
1.0 mm
Nominal outer sheath thickness
1.4 mm
Nominal overall diameter
12.9 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.638 Ohm/km
Inductive reactance at 50Hz - flat touching
0.113 Ohm/km
Inductive reactance at 50Hz - trefoil
0.098 Ohm/km
Insulation resistance at 20°C
290 MOhm.km
Max. DC resistance of the conductor at 20°C
0.387 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pull Tension of Conductor
4 kN
Maximum Pulling Tension
1.5 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
150 mm
Minimum Bend Radius - Installed
100 mm
Resources
Resources
XLPE/PVC single core - Current carrying capacity table single phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 228.0 | 177.0 | 216.0 | 167.0 | 176.0 | 136.0 | 166.0 | 129.0 | 133.0 | 103.0 | 0.0 | 0.0 | 255.0 | 198.0 | 189.0 | 147.0 | 211.0 | 164.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
XLPE/PVC single core - Current carrying capacity table three phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 221.0 | 171.0 | 188.0 | 146.0 | 176.0 | 136.0 | 143.0 | 111.0 | 114.0 | 89.0 | 0.0 | 0.0 | 214.0 | 166.0 | 163.0 | 126.0 | 190.0 | 147.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |