ENVIROLEX® TPS Low Fire Hazard (LSZH and non-migratory)

Products

2C+E 1.5mm2 Cu 450/750V, X-HF-90, HFS-90-TP Grey, TPS to AS/NZS 5000.2, 500m

Nexans ref. CTCP05J5002GXHF

  • Packaging: Spool (500m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Nominal overall diameter: 10.0 x 4.6
  • Approximate weight: 9.1 kg/100m
  • Maximum installation tension: 210 N
  • Minimum Bend Radius - During Installation (under Tension): 27 mm
  • Minimum Bend Radius - Installed: 18 mm

 

2C+E 2.5mm2 Cu 450/750V, X-HF-90, HFS-90-TP Grey, TPS to AS/NZS 5000.2, 500m

Nexans ref. CTCP07J5002GXHF

  • Packaging: Spool (500m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Nominal overall diameter: 12.2 x 5.4
  • Approximate weight: 14.1 kg/100m
  • Maximum installation tension: 350 N
  • Minimum Bend Radius - During Installation (under Tension): 33 mm
  • Minimum Bend Radius - Installed: 22 mm

 

2C+E 4mm2 Cu 450/750V, X-HF-90, HFS-90-TP Grey, TPS to AS/NZS 5000.2, 500m

Nexans ref. CTCP09J5002GXHF

  • Packaging: Spool (500m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Nominal overall diameter: 13.9 x 6.3
  • Approximate weight: 18.9 kg/100m
  • Maximum installation tension: 560 N
  • Minimum Bend Radius - During Installation (under Tension): 39 mm
  • Minimum Bend Radius - Installed: 26 mm

 

2C+E 6mm2 Cu 450/750V, X-HF-90, HFS-90-TP Grey, TPS to AS/NZS 5000.2, 500m

Nexans ref. CTCP11J5002GXHF

  • Packaging: Spool (500m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Nominal overall diameter: 15.0 x 6.9
  • Approximate weight: 23.3 kg/100m
  • Maximum installation tension: 840 N
  • Minimum Bend Radius - During Installation (under Tension): 42 mm
  • Minimum Bend Radius - Installed: 28 mm

 

Description

Description

ENVIROLEX® flat is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) cable, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.

Application

  • Low Fire hazard cable designed for public buildings where safe evacuation time is a consideration (hospitals etc).
  • Suitable for general power and lighting construction purposes.
  • Domestic, commerical and industrial applications where low smoke or halogen free products are required.
  • Fixed applications.
  • Low Fire Hazard (low smoke halogen free cable LSZH/LS0H).
  • This product is non-migratory. It can be in contact with other plastic compounds such as polyurethane and polystyrene without any adverse effects. Suitable for use in cool rooms and in-contact with thermal insulation materials.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Grey
Conductor material
Copper
Type of conductor
Stranded copper
Conductor flexibility
Class 2
Conductor shape
Circular
Insulation
X-HF-90
Outer sheath
HFS-90-TP
With Green/Yellow core
Yes

Dimensional characteristics

Dimensional characteristics

Cable length
500 m
Number of cores
2
Number of earth cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U
450/750 V
Rated Voltage Uo/U (Um)
-

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Minimum operating temperature
-25 °C
Smoke density
Low

Resources

Resources

Documentation

pdf — 1.6 MB

Envirolex Flat With Earth - Current carrying capacities single phase (in Amps)

Copper Conductor

Insulation XLPE

Maximum Conductor Temperature 90⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu
1.0 18.0 17.0 14.0 9.0 16.0 12.0 8.0 19.0
1.5 24.0 22.0 18.0 11.0 20.0 16.0 10.0 24.0
2.5 34.0 31.0 25.0 16.0 28.0 23.0 14.0 34.0
4.0 45.0 42.0 55.0 21.0 37.0 29.0 18.0 45.0
6.0 57.0 53.0 42.0 27.0 46.0 37.0 23.0 56.0
10.0 78.0 73.0 58.0 37.0 63.0 51.0 32.0 75.0
16.0 104.0 97.0 78.0 49.0 82.0 66.0 41.0 98.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Underground ducts

Selling & delivery Information

Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close